The world’s hottest hot bonder, the WichiTech HB-2 is a powerful, portable composite repair system that sets industry standards for ease of operation, safety, reliability and value. This durable system repairs metal, Kevlar, carbon, boron and fiberglass simply, safely and cost-effectively. HB-2 makes fast, flawless work of large or small repair jobs. The 35 pound USA-built unit is as simple to program as a microwave with its easy-to-read digital display and menu listed functions.
The custom made HB-2 is individually manufactured to your specifications. Select from a single zone unit up to a dual zone unit with two independent programmed heating zones, 20 amps each, and two individual adjustable vacuum zones or anywhere in between.
These twin features permit you to perform two independently-programmed cures simultaneously. Fail-safe protection is provided by the monitoring of multiple thermocouples, and audible alarms guard against temperature and vacuum conditions that could ruin the repair. Rugged field proven components shock mounted inside a tough, impact-resistant case mean years of reliable service from the HB-2 value engineered for first-time, every-time top of the line performance.
Items | HB-2 Single Zone Composite Repair System |
Weight | 45 Pound |
NSN | |
Model | HB2007 |
Heating Zones | 1- Operator Programmable in Bonder and/or Monitor modes |
Heating System | Electric Blanket, Heat Lamps, Heat Gun |
Heat/Dwell Steps | 1 to 6 |
Heat Up Rate | 1º to 15º in 1º increments °F/minute |
Dwell Temperature | 500 ºF |
Dwell Time | 0 to 999 minutes in 1º increments |
Cool Down Rate | 1º to 15º F/minute in 1º increments (passive) |
Temperature Accuracy | ±5 ºF |
Heat Blankets | 10" x 10" and 12" x 12" (110 V & 220 V) Standard |
Thermocouple | |
Active Thermocouple Inputs | 8 (Control and Backup) |
Vacuum Pump (Standard) | Oil-Free, Electric, 0.90 CFM |
External Vacuum | |
Vacuum Lines | 1 with thru-bag connector |
Active Vacuum Transducers | 1 (0" to 30" Hg) |
Alarm Conditions | Low Vacuum, Open Thermocouple, Under Temperature, Over Temperature, Backwards T/C, Failed T/C, Blanket Control Failure (No Heat) |
AC Power Supply | Auto-switching 85-265 Volts, 47-440 Hz, 20 Amp (400 Hz at 115 VAC) |
AC Safety Devices | Circuit Breaker - 20 Amp |
Size | 21" x 14" x 8" |
Standard Features |
|